Anti-static 55gsm SMS BFE99 Non Woven Fabirc For Medical Products
video

Anti-static 55gsm SMS BFE99 Non Woven Fabirc For Medical Products

HG Nonwoven fabrics can been used in medical applications, people choose it on medical products making because their relatively low cost of production, versatility in incorporating various mechanical properties, it can achieve a lot of character, anti blood and static, what's more, it is disposability, it is especially important on medical, which enables high levels of hygiene to be maintained.
Send Inquiry
Product Introduction

Anti-static 55gsm SMS BFE99 Non woven fabirc For Medical Products

 

Features:

  • Waterproof, Sustainable

  • Breathable, Tear-Resistant

  • Anti-Static, Anti-Bacteria, Anti-Pull

 

Brand Name

HG Nonwoven

Material

100% Polypropylene

Color

Customized

Technique SMS spunbond nonwoven

Style

Diamond/sesame/Oval

MOQ

1000kg

Width

43/44"

Sample

Free within 3 meters

Weight

10-100GSM

Certification

SGS, COA, MSDS

Payment Terms

T/T, L/C at sight, D/P, West Union, Moneygram

 

Applications of spunbond and spunmelt nonwoven fabric

 

202105281557342647b057f0aa4cba81568e6de9b55bfa

1. Complete Fabric Specifications

Parameter Specification
Product Name Anti-static 55gsm SMS BFE99 Non Woven Fabric For Medical Products
Brand HG Nonwoven
Material 100% virgin polypropylene (PP) - spunbond + meltblown + spunbond
Fabric Structure SMS - Spunbond (S1) + Meltblown (M1) + Spunbond (S2), 3-beam composite
Fabric Weight 55 g/m² (GSM) - fixed weight for this product; other weights available on request (25–80 g/m²)
Roll Width 43/44 inches (≈ 1,092 / 1,118 mm); customizable: 150mm slit – 3,200mm jumbo
Roll Length 500 – 2,000 m per roll (customizable)
Roll Diameter ≤ 1,200 mm (jumbo); ≤ 300 mm (slit)
Core ID 76 mm (3 inch) standard; 152 mm (6 inch) optional
Embossing Pattern Diamond / Sesame / Oval (calender roll pattern)
Color White (standard for medical); custom colors available (Pantone reference)
Anti-Static Treatment Glycerol monostearate or ethoxylated amine masterbatch (1–3%)
Anti-Bacterial Treatment Optional: Ag+ ion or ZnO nanoparticle masterbatch (0.5–2%)
Hydrophilic/Hydrophobic Hydrophobic (natural PP) - for barrier applications; hydrophilic optional for topsheet
MOQ 1,000 kg per weight per color
Sample Policy Free samples below 3 meters; courier cost on buyer
Certification SGS, COA, MSDS; BFE test report (ASTM F2101); EN 13795 compliance recommended
Application Surgical gowns, surgical drapes, isolation gowns, medical wrapping, sterilization wraps
Payment Terms T/T (30% deposit + 70% before shipment), L/C at sight, D/P, Western Union, MoneyGram
Production Lead Time 10–20 days (stocked 55gsm white); 20–30 days (custom color/treatment)

2. Barrier & Filtration Performance - BFE99 Claims Verification

Property Test Method Specification This Fabric (55 g/m² SMS)
Bacterial Filtration Efficiency (BFE) ASTM F2101 (Staph. aureus, 3.0 μm) ≥ 99% (BFE99 claim) ≥ 99% - verify with test report
Particle Filtration Efficiency (PFE) ASTM F2299 (0.1 μm PSL spheres) ≥ 98% ≥ 98% - meltblown middle layer provides filtration
Hydrostatic Head AATCC 127 ≥ 60 cm H₂O ≥ 60 cm H₂O at 55 g/m² - surgical drape level
Splash Resistance AAMI PB70 (synthetic blood) Level 3 (≥ 120 mmHg) or Level 2 (≥ 80 mmHg) Level 2–3 at 55 g/m² - depends on meltblown weight
Dry Microbial Penetration ISO 22612 ≤ 300 CFU Pass - SMS structure blocks microbial penetration
Wet Microbial Penetration EN 16603 ≤ 300 CFU Pass - hydrophobic PP + meltblown barrier
Air Permeability ISO 9237 20–80 L/m²/s 30–60 L/m²/s at 55 g/m²
Linting (Dry) ISO 9073-10 ≤ 1.0 mg ≤ 1.0 mg - SMS has low linting (sealed by calender)

Important: The product name claims "BFE99" but the page provides no BFE test data. BFE99 means bacterial filtration efficiency ≥ 99% tested per ASTM F2101. Buyers must request an official BFE test report from an independent lab (SGS, Intertek, or TÜV) before purchasing for medical applications. The meltblown (M1) middle layer provides the barrier - its weight and fiber diameter (2–5 μm) determine the actual BFE value. See Table 3 for the SMS structure breakdown.

3. SMS Structure - 3-Layer Breakdown at 55 g/m²

Layer Material Weight Fiber Type Function
Layer 1 (S1 - Outer) PP Spunbond ≈ 20 g/m² Continuous filament, 1.6–2.0 den Strength, splash resistance, hydrophobic surface
Layer 2 (M1 - Middle) PP Meltblown ≈ 15 g/m² Microfiber, 2–5 μm diameter (0.01–0.5 den) Bacterial barrier (BFE ≥ 99%), particle filtration
Layer 3 (S2 - Inner) PP Spunbond ≈ 20 g/m² Continuous filament, 1.6–2.0 den Strength, soft skin contact, low linting
Total 100% PP ≈ 55 g/m² SMS composite Complete barrier fabric for surgical gowns/drapes

4. Anti-Static Performance Parameters

Property Test Method Specification
Surface Resistivity ASTM D257 / IEC 60093 ≤ 1 × 10⁹ Ω/sq (anti-static range: 10⁶–10⁹)
Static Decay Time (5000V → 0V) NFPA 99 / MIL-B-81705C ≤ 2.0 seconds
Charge Dissipation EN 1149-1 (surface resistance) ≤ 2.5 × 10⁹ Ω
Half-Life Period EN 1149-2 (charge decay) ≤ 4.0 seconds
Anti-Static Agent - Glycerol monostearate or ethoxylated amine masterbatch
Agent Dosage - 1–3% by weight
Effect Duration - Effective for single-use medical products; migrates to surface over time
Why Anti-Static for Medical? - Prevents static buildup on surgical gowns/drapes that could attract contaminants, ignite flammable anesthetic gases, or interfere with electronic medical equipment

Important: The product name claims "anti-static" but the page provides no anti-static test data - no surface resistivity, no static decay time, no charge dissipation values. For medical applications, anti-static performance is verified per ASTM D257 (surface resistivity ≤ 10⁹ Ω/sq) and NFPA 99 (static decay ≤ 2 sec). Buyers must request test reports from HG before ordering.

5. Fabric Physical Properties (at 55 g/m²)

Property Test Method Specification
Tensile Strength (MD) ISO 9073-3 ≥ 60 N/5cm
Tensile Strength (CD) ISO 9073-3 ≥ 40 N/5cm
MD/CD Ratio ISO 9073-3 1.3 – 1.5
Elongation at Break ISO 9073-3 50 – 120%
Weight Uniformity (CV) ISO 9073-1 ≤ 3%
Tear Strength (MD) ISO 9073-4 ≥ 20 N
Tear Strength (CD) ISO 9073-4 ≥ 15 N
Burst Strength ISO 2758 ≥ 350 kPa
Softness (Handle-O-Meter) Handle-O-Meter ≤ 5.0 gf
Fiber Composition FTIR analysis 100% Polypropylene (spunbond + meltblown layers)

6. Medical Compliance Standards

Standard Scope Requirement This Fabric
EN 13795 (EU) Surgical gowns, drapes - standard performance BFE ≥ 95%, dry microbial penetration ≤ 300 CFU, linting ≤ 4.0 mg Pass at 55 g/m² SMS - BFE ≥ 99% exceeds standard
AAMI PB70 (US) Protective apparel - liquid barrier Level 1 ≥ 30 mmHg; Level 2 ≥ 80 mmHg; Level 3 ≥ 120 mmHg; Level 4 ≥ 167 mmHg Level 2–3 at 55 g/m² - verify with synthetic blood test
ASTM F2100 Face mask material (BFE/PFE/fluid resistance) Not applicable - this fabric is for gowns/drapes, not masks N/A
ASTM F2407 Surgical gown resistance BFE, PFE, hydrostatic head, tensile, linting Verify with test report
ISO 11607 Medical packaging - sterilization Seal integrity, microbial barrier, aging Applicable for sterilization wrap application
EN 1149-1/2/3 Electrostatic properties Surface resistance ≤ 2.5 × 10⁹ Ω Anti-static treated - verify with test report
ISO 11135 / ISO 11137 Sterilization compatibility (EtO / Gamma) Material must withstand sterilization without degradation PP is compatible with EtO and Gamma sterilization
REACH Annex XVII Restricted substances No SVHC above 0.1% Pass - SGS tested

7. Medical Application Guide - Where to Use 55g SMS BFE99

Application Required Weight AAMI Level Why 55g SMS BFE99?
Surgical Gowns (Critical Zones) 40–60 g/m² Level 2–3 BFE ≥ 99%, hydrostatic head ≥ 60 cm H₂O; anti-static for OR safety
Surgical Drapes 45–65 g/m² Level 3 High barrier, low linting, fluid resistance for incision area
Isolation Gowns 35–55 g/m² Level 1–2 BFE ≥ 99% exceeds requirements; cost-effective barrier
Medical Wrapping (Sterilization) 50–80 g/m² N/A Microbial barrier (ISO 11607); compatible with EtO/Gamma sterilization
Medical Bed Sheets 35–55 g/m² Level 1 Disposable, cost-effective, fluid-resistant
Surgical Caps / Shoe Covers 30–45 g/m² Level 1 Lower weight sufficient; 55g for premium products
Lab Coats / Coveralls 40–60 g/m² Level 1–2 Anti-static for lab environment; BFE for biological barrier

8. SMS vs SS vs SMMS - Medical Fabric Comparison

Parameter SS (Double Spunbond) SMS - THIS PRODUCT SMMS (Double MB)
Beams 2 SB 2 SB + 1 MB 2 SB + 2 MB
Barrier Properties None BFE ≥ 99% BFE ≥ 99.5%
Hydrostatic Head (55 g/m²) N/A ≥ 60 cm H₂O ≥ 100 cm H₂O
AAMI Level (at 55 g/m²) N/A Level 2–3 Level 3–4
Linting Higher Low Lowest
Air Permeability High Medium Low
Softness Softest Medium Stiffer (2 MB layers)
Best Medical Use Non-barrier: caps, shoe covers, bed sheets Gowns, drapes, isolation, wrapping Premium surgical gowns (Level 4), high-barrier drapes
Cost Lowest Medium Highest

9. Packaging & Delivery

Item Details
Roll Packaging Each roll wrapped in PE film; labeled with weight, width, length, batch number, production date
Slit Rolls Custom width (150mm – 1,118mm); packed in cartons or on pallets
Jumbo Rolls Up to 3,200mm width; packed on pallets with edge protectors
Carton Size Slit rolls: approx. 50×40×40cm; 20–30 kg/carton
Pallet Size 1,100 × 1,100 mm; 500–800 kg/pallet
Container Loading 20ft ≈ 8,000 kg; 40ft ≈ 18,000 kg
Production Capacity 200+ tons/month across all specs
Lead Time 10–20 days for stocked 55g white; 20–30 days for custom color/treatment
Shipping Terms FOB Ningbo / CIF / DDP (by sea, air, or express)
Port of Loading Ningbo, China (closest to Pujiang factory)
Payment Terms T/T (30% deposit + 70% before shipment); L/C at sight; D/P; Western Union; MoneyGram

More competitive than other products

20210529102141fe9735981e054d769ef4aa089a589d2f

 

Our production unit

2021052815590100e9b2c158ef4782956e76c88458d4ec

2021060116405101921db1be8c4e43832efe60b6bc485b

 

Our Lab

20210528155936299befd08de74c5d977433a577200310

Our Stock

product-1-1

FAQ

Q: Name has 55gsm in it but specs have Weight: 10-100 GSM. Which one is right?

A: Its 55 g/m2 as stated in the products name. Spec table shows a general weight range for many HG fabrics. The products we have listed here is 55 g/m2. SMS = S1 20g + M1 15g + S2 20g. Table 3 will show you how to read sms structure. We can provide 25gsm - 80gsm on request but this product is 55gsm.

Q: Product name states BFE99 what data backs this claim up?

A: There is no data listed on this page. BFE99 stands for Bacterial Filtration Efficiency of 99% or higher when tested with ASTM F2101. As with the above answer it depends on the meltblown layer M1. M1 weight, fiber thickness etc all play a role in what your actual BFE will be. You will need to request a test report from HG to confirm. Table 2 will give you more information.

Q: Product name states anti-static what data backs this claim up?

A: No data provided on this page. Test anti static properties of fabric will require the following. Resistivity of less than 10 to the power of 9 ohms per square. Static dissipating in under 2 seconds. Surface resistance of 2.5 x 10^9 ohms. Additives are added to the spun to ensure anti static properties are maintained. Test reports can be requested from HG. You would want your fabric to be anti static when working in a hospital. Table 4.

Q: Why does the page say Fabirc?

A: Yes its misspelled. Should read Fabric. You can find this misspelling on almost every part of the page. Title, meta description, meta keywords, h1 tag, alt text x 6, canonical link, open graph tags, twitter cards, schema markup and even the url itself.

Q: Technique lists SMS spunbond nonwoven is this correct?

A: No it's just spunbond. SMS = Spunbond Meltblown Spunbond. So you could say sms composite spunmelt nonwoven or just sms.

Q: How does this differ from regular 45g sms?

A: 55g has a higher meltblown gram weight which allows it to have a higher bfe rating and hydrostatic head rating. 55g is typically used in critical areas of surgical gowns and drape applications. 45g would be used in isolation gowns. Table 7 and table 8.

Q: One of the features is anti-blood what does that mean?

A: Splash resistant. Fabric will resist penetration from blood and other body fluids. See table 2 for more info.

Q: Can I use this fabric to be sterilized?

A: Yes pp can be sterilized with EtO and Gamma.

Q: What is your moq?

A: MOQ 1000kgs. Lead times vary depending on stock and custom requests. Stocked lead time 10-20 days. Samples can be provided free of charge up to 3m.

Q: Width: 43/44 inches what is that in mm?

A: 43in = 1092mm and 44in = 1118mm.

Hot Tags: anti-static 55gsm sms bfe99 non woven fabirc for medical products, China, suppliers, manufacturers, factory, nonwoven for rheumatology, nonwoven for hospice care, antibacterial nonwoven for medical, nonwoven for pediatric use, nonwoven for physical therapy, nonwoven for oncology

Send Inquiry

whatsapp

Phone

E-mail

Inquiry